网站首页产品展示德国Honsberg德国honsberg流量计 > *德国HONSBERG变送器
*德国HONSBERG变送器

*德国HONSBERG变送器

所属分类:德国honsberg流量计

更新时间:2016-02-25

简要描述:*德国HONSBERG变送器
德国Honsberg豪斯派克流量计公司是欧洲历史悠久的一家流量计公司,现在属于GHM测量技术集团。产品涵盖流量,压力,温度,液位测量等。

详细说明:

品牌HONSBERG/豪思派克

*德国HONSBERG变送器

Photo

Type

Description

Measuring input/

Process connection

Documents

pH9648

 

 

pH and ORP 数字面板表
4-digit, 14.2 mm red, 
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
max. 4 alarm outputs,
Analog output,
Supply voltage: 24 V DC, 24 V AC, 115 V AC, or 230 V AC
Panelmeter DIN 96x48mm

Direct connection of pH- and ORP- electrodes

-1.00..15.00 pH;

±1500 mV

 Data sheet

 Manual

UNICON-pH

 

 

pH and ORP 转换器
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
Output 4..20 mA for
pH/ORP and temperature,
max. 2 alarm outputs,
Loop voltage: 14..30 V DC,2-wire,
Field- or head mounting

Direct connection of pH- and ORP-electrodes

-1.00..15.00 pH;

±1500 mV

Data sheet
Manual

Accessories:
Connection cables, Calibration tools

pH40

 

 

pH-Head 变送器
2-wire-transmitter 4..20 mA,
Direct mounting at the electrode,
Measurement up to 100 m

 

 

-1..15 pH/±1500 mV

 Data sheet

GPHU

 

 

pH-Transmitter

温度补偿 via Pt1000,

Output 0..10 V (3-wire)

4..20 mA (2-wire),

LC-Display 4 digits,

Supply voltage:

12..30 V DC at 4..20 mA

18..30 V DC at 0..10 V

Direct connection of pH electrodes via plug

0.00..14.00 pH;

 Data sheet

 

  
  
  

 

 

pH/ORP-电极

 

0..14 pH

 

 Data sheet

接头

EA1200/EA2200

 

 

In-line Fitting

for pH/ORP-electrodes with integrated tip protection

 

Material PVC-U acc. to DIN 8061 and 8062

for Flow-fitting DFA32

 Data sheet

EA1630/EA2630

 

 

In-line Fitting

for pH/ORP-electrodes with integrated tip protection

 

Material PVDF

Whitworth thread acc. to

DIN ISO 228

 Data sheet

EA1730/EA2730

 

 

卫生线路接头

for pH/ORP-electrodes with integrated tip protection

 

Material PVDF

FDA conform

Milk pipe acc. to

DIN 11887

 Data sheet

EA2650              

 

 

In-line Fitting

for pH/ORP-electrodes

 

Material SS-type 1.4571

Process connection

G1/2A, G3/4A, G1A

 Data sheet

WA120              

 

 

转换接头

for pH/ORP-electrodes

Changing of electrodes without process interruption

 

Process material SS-type 1.4571

Process connection

G3/4A

 Data sheet

DFG              

 

 

溢流柜

for pH/ORP-electrodes

 

Material SS-type 1.4571

Process connection

PG13.5, G1/4A, G1A

 Data sheet

 

Honsberg电导仪表

Photo

Type

Description

Measuring input/

Process connection

Documents

LF9648

 

电导表

4-digit, 14.2 mm red,

Measuring range programmable,

Temperature compensation via Pt100/Pt1000,

max. 4 alarm outputs,

Supply voltage:

24 V DC, 24 V AC, 115 V AC, 230 V AC,

Panelmeter DIN 96x48mm

 

Direct connection of 2- or 4- electrode cells,

0..2000 mS/cm

 

 Data sheet

 Manual

LF1010

 

Conductivity Meter

4-digit, 14.2 mm red,

Measuring range programmable,

Temperature compensation via Pt100/Pt1000,

max. 2 alarm outputs,

Supply voltage:

24 V DC, 24 V AC, 115 V AC, 230 V AC,

Field mounting

 

Direct connection of 2- or 4- electrode cells,

0..2000 mS/cm

 

 Data sheet

 Manual

UNICON-LF

 

Conductivity-Converter

Measuring range programmable,

Temperature compensation via Pt100/Pt1000,

Output 4..20 mA for

conductivity and temperature,

max. 2 alarm outputs,

Supply voltage: 14..30 V DC,

Loop powered,

Field- or head mounting

 

 

Direct connection of 2- or 4- electrode cells,

0..2000 mS/cm

 

 Data sheet

 Manual

GLMU

 

 

Conductivity Transmitter incl. Cell

Temperature compensation,

Output 0..1/10 V (3-wire)

4..20 mA (2-wire),

LC-Display 4 digit,

Supply voltage:

12..30 V DC at 4..20 mA

18..30 V DC at 0..10 V

Direct connection of 2- or 4-electrode cells via plug

200 µS/cm..500 mS/cm

 Data sheet

电导电池

LF2203

 

 

2-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PVC-U DIN 8061/8062, Graphite (electrodes)

For flow fitting DFA25

Pipe diameter 25..63 mm,

 

Measuring range:

100 µS/cm..2 mS/cm

 Data sheet

LF2603

 

 

2-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PVC-U DIN 8061/8062,

SS-type (electrodes)

Process thread G1/2A, G3/4A, R1/2, G3/4,


Measuring range:

20 µS/cm..100 µS/cm

 Data sheet

LF2613

 

 

2-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PVC-U DIN 8061/8062,

Electrodes (Graphite)

Process thread G1/2A, G3/4A, R1/2, G3/4


Measuring range:

100 µS/cm..2 mS/cm

 Data sheet

LF2653HT

 

 

2-Electrode High Temperature

Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Temperature range 0..200 °C,

Process material SS-type 1.4404, ceramic

Process thread G3/4A, G1A, G1 1/4A


Measuring range:

0.5 µS/cm..50 µS/cm

 Data sheet

LF1453/LF2453

 

 

2-Electrode Ultra-pure water

Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material SS-type, PVDF,

Field or head mounting

Clamp-connection acc. to DIN 32676 or Südmo-Aseptik


Measuring range:

0.5 µS/cm..50 µS/cm

 Data sheet

LF1553/LF2553

 

 

2-Electrode Ultra-purewater

Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material SS-type 1.4404, PEEK,

Field or headmounting

VARIVENT Inline-case


Measuring range:

0.5 µS/cm..50 µS/cm

 Data sheet

LF1653/LF2653

 

 

2-Electrode Ultrapure water

Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material SS-type 1.4404 electropolished, PVDF,

Field or headmounting

Process thread G3/4A, G1A

Measuring range:

0.5 µS/cm..50 µS/cm

 Data sheet

LF4003                

 

 

4-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PVC-U, casting resin, SS-type 1.4305, Graphite (electrodes), PUR cable

Immersion Cell up to 100 m depth of water


Measuring range:

20 µS/cm..500 mS/cm

 Data sheet

LF3043/LF4043                

 

 

4-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PA, casting resin, Graphite (electrodes)

Field- or head mounting

Immersion-cell for ducts, basins and open systems


Measuring range:

20 µS/cm..500 mS/cm

 Data sheet

LF3213/LF4213                

 

 

4-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PVC-U, casting resin, Graphite (electrodes)

Field- or head mounting

For Flow fitting DFA32

and pipe diameter 20..63 mm


Measuring range:

20 µS/cm..500 mS/cm

 Data sheet

LF3433/LF4433                

 

 

4-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PEEK, PVDF, SS-type 1.4404, Graphite (electrodes)

Field- or head mounting

Clamp-connection acc.. to DIN 32676

Measuring range:

20 µS/cm..500 mS/cm

 Data sheet

LF3533/LF4533                

 

 

4-Electrode Hygienic

Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PEEK, SS-type 1.4404, Graphite (electrodes)

Field- or headmounting

VARIVENT Inline-case


Measuring range:

20 µS/cm..500 mS/cm

 Data sheet

LF3623/LF4623                

 

 

4-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PVDF, casting resin, Graphite (electrodes)

Field- or headmounting

Process thread G3/4A, G1A acc. to DIN ISO 228

Measuring range:

20 µS/cm..500 mS/cm

 Data sheet

LF3733/LF4733                

 

 

4-Electrode Conductivity Cell

integrated Pt1000 sensor for temperature compensation,

Process material PEEK, PVDF, SS-type 1.4404, casting resin, Graphite (electrodes),

Field- or headmounting

Milk pipe connection acc. to DIN 11887,

Measuring range:

20 µS/cm..500 mS/cm

 Data sheet

Accessories

 

Connection cables

Calibration tools

 

 

 

 Data sheet

O2, CO, CO2,氧气,一氧化碳,二氧化碳变送器

Photo

Type

Description

Measuring range

Documents

OXY 3690 MP

Air oxygen transmitter incl. sensor

Oxygen concentration:
0,0..100,0 % O2

Data sheet

OXY 3610 MP

Transmitter incl. sensor for dissolved oxygen in liquids

Oxygen concentration:
0,00..25,00 mg/l (dissolved)

Data sheet

GT1-CO

CO-transmitter

Carbon monoxide:
0..300 ppm CO

Data sheet

GT10-CO2-1R

CO2-transmitter

Carbon dioxide:
0..2000 ppm CO2 or 
0..5000 ppm CO2

Data sheet

 

*德国HONSBERG变送器

<br>HONSBERG流量开关
HONSBERG流量开关  HONSBERG流量开关产品覆盖涵盖流量,也为,压力,和温度测量。测量介质:水,腐蚀性介质液体和油类!
 
<br>代理HONSBERG流量开关VOR-025GM0900
代理HONSBERG流量开关VOR-025GM0900 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VOR-025GA0450
代理HONSBERG流量开关VOR-025GA0450 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VOR-015GM0080
代理HONSBERG流量开关VOR-015GM0080 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VM.WPS.66.RI.IP65-21/2 BSP
代理HONSBERG流量开关VM.WPS.66.RI.IP65-21/2 BSP 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VM-050GR250-220
代理HONSBERG流量开关VM-050GR250-220 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VM-040GR150T
代理HONSBERG流量开关VM-040GR150T 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VM-032GR100
代理HONSBERG流量开关VM-032GR100 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VM-025GR060
代理HONSBERG流量开关VM-025GR060 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VM- 050GR250
代理HONSBERG流量开关VM- 050GR250 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG齿轮流量计VHZ-020GA050N-5
代理HONSBERG齿轮流量计VHZ-020GA050N-5 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG齿轮流量计VHZ-020GA050E+LABO-VHZ-020IPS
代理HONSBERG齿轮流量计VHZ-020GA050E+LABO-VHZ-020IPS 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG齿轮流量计VHZ-020GA050A
代理HONSBERG齿轮流量计VHZ-020GA050A 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG齿轮流量计VHZ-010GA006P
代理HONSBERG齿轮流量计VHZ-010GA006P 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG齿轮流量计VHZ-010GA006N
代理HONSBERG齿轮流量计VHZ-010GA006N 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG齿轮流量计VHZ-008GA002P
代理HONSBERG齿轮流量计VHZ-008GA002P1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VDO-040GR100
代理HONSBERG流量开关VDO-040GR100 1、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VD-040GR100
代理HONSBERG流量开关VD-040GR1001、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 
<br>代理HONSBERG流量开关VD-015GR010
代理HONSBERG流量开关VD-015GR0101、弹簧支撑活塞和磁性触发簧片开关
2、机械式流量开关,带有粘性补偿
3、铜或者不锈钢制作,结构坚固,抗污染
 


上海富肯机电泵类产品:比利时Packo离心泵,美国Magnatex磁力泵,美国S&K喷射泵,美国Discflo盘片泵,意大利OMAC卫生泵,荷兰Pomac泵,意大利3M磁力泵,德国KSB,韩国JEC卫生泵,德国Knoll,德国Kral

安全阀:德国,美国Crosby,德国Herl,德国Herose,德国Andreas Hofer,德国Ni(Niezgodka),意大利Besa,意大利FEMA,美国Flowsafe,美国Mercer,意大利Technical,德国Krombach,澳大利亚MACK安全阀

球阀:德国Romann,德国Argus,芬兰Jouka,德国Bohmer,意大利Adler,美国Volk,美国Pister,德国EA,波兰Andrex,荷兰ECONOSTO,德国A+R,德国AWH,韩国Fluonics等,德国COAX,德国GSR,德国Mankenberg,英国STAR

蝶阀:西班牙TTV,荷兰Wouter Witzel,德国Zwick,法国Tecofi,荷兰Econosto,德国KSB,德国Krombach

气动执行器:意大利AirTorque,意大利GT,德国Rotadisk,英国Kinetrol,德国Bar等,德国ARIS,德国EMG,德国Auma

优势品牌:德国Honsberg,德国Mankenberg,德国Rotech,德国Airtec,意大利ATOS,日本CKD,日本TOYOOKI,英国Norgren,德国EMGHydac,德国BENDER,德国Microsonic,德国DINA,美国SUN,美国Dart control,德国Bucher,德国Disoric等,德国SUCO,德国Wika,德国Kubler,德国Kuebler,德国Ksr-kuebler.德国Ac-motoren,德国ADDI-DATA,德国ATB,德国Aviteq,德国AVTRON,德国Dopag,美国FORMSPRAG,美国Warner,德国FSG,美国hedland,德国HERZOGINTERNORMENIPF,P+F,德国Jacob,德国Jumo,德国Knick,德国Lika,意大利Lovato,德国MGV,德国MGV Stromversorgungen GmbH,德国MOOG,德国PALL,德国Pauly,德国Pilz,德国Pinter,德国ROEMHELD,德国Rohm GmbH,德国TOX,德国BECK,德国Ahlborn等

*,欢迎您的垂询!

 



留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7